Capital City Mechanical Blog
SWUD Replacement Made Easy!
Tuesday, 29 November 2011 21:59

Introducing Modular units from Mammoth!
- Easily disassembles to fit through 36" door
- Double wall construction
- Digital scroll compressor for VAV efficiency without Hot Gas Bypass
- Quiet FANWALL technology for efficiency and quiet operation
- Built in open protocol DDC controls for integration or future expansion
Let Capital City show you how to upgrade the noisy energy hog in your mechanical room!
Digital Direct Controls
Friday, 30 September 2011 00:00
Summary
Capital City Mechanical, Inc. is Atlanta's best place to go for Digital Direct Control of your building HVAC. We deliver complete solutions for Energy Management, Building Automation, Green Building and other requirements for facility control.
Benefits
There are many benefits to be realized by deploying DDC technology in your commercial building:
- You will save money
- You will save energy
- Your building will be more comfortable
- Your systems will be more reliable
- You will have more control.
Features
Energy Savings and Precise Climate Comfort - A Building Control System can optimize the comfort and lighting of your building while decreasing the overall runtime of your equipment, thus lowering total energy consumption. Temperature schedules and equipment controls can be set up to use outside air when suitable, lock out the chiller on low temperature days, and optimize low occupancy and nighttime climate settings.
Improved Reliability - Automated building control systems can deliver automated alarm and event notifications via email, pager, or text message to notify maintenance staff and building management if action is needed.
Return On Investment
Return on Investment (ROI) varies greatly from project to project, but savings are well documented and predictable. It is not unusual for DDC projects to pay for themselves in less than a year. Call us for an analysis of your facility and a customized proposal including anticipated ROI.
Service Contracts
Thursday, 15 September 2011 00:00

Heating and Cooling systems have a way of breaking down just when the weather turns.
Why do I need a Preventative Maintenance (PM) Contract?
A PM contract generally includes a number of scheduled and rigorous activities such as changing belts and filters, cleaning indoor and outdoor coils, lubricating motors and bearings, cleaning and maintaining cooling towers, testing control functions and calibration, and painting for corrosion control.
The main advantage of this type of contract is that it is initially less expensive than either a full-service or full-labor contract and provides the owner with an agreement that focuses on quality preventive maintenance.
Data Center Cooling Solution Primer
Tuesday, 30 August 2011 00:00
Capital City has installed dozens of sophisticated data center cooling projects, this article from noted data center consultants 42U is one of the best we have seen for giving someone who is just getting started a really great overview.
The cooling infrastructure is a significant part of a data center. The complex connection of chillers, compressors and air handlers create the optimal computing environment, ensuring the longevity of the servers installed within and the vitality of the organization they support.
Read the article, then call us to get your project started. We're the experts.
Data Center Cooling [www.42u.com]